Name: 'COMP: Timeserver configuration (W32Time)'
Type: Object
LinkedOUs:
- OU=Domain Controllers
WMIFilters:
- PDC Emulator
RegistryEntries:
- Key: HKLM\SYSTEM\CurrentControlSet\Services\W32Time\Parameters
Type: String
ValueName:
- Type
- NtpServer
Value:
- NTP
- "{{ addsconfig.ntpserver }}"
- Key: HKLM\SYSTEM\CurrentControlSet\Services\W32Time\Config
Type: DWord
ValueName: AnnounceFlags
Value: 0xA
- Key: HKLM\SYSTEM\CurrentControlSet\Services\W32Time\Config
Type: DWord
ValueName: MaxPosPhaseCorrection
Value: 0xFFFFFFFF
- Key: HKLM\SYSTEM\CurrentControlSet\Services\W32Time\Config
Type: DWord
ValueName: MaxNegPhaseCorrection
Value: 0xFFFFFFFF
- Key: HKLM\SYSTEM\CurrentControlSet\Services\W32Time\TimeProviders\NtpServer
Type: DWord
ValueName: Enabled
Value: 1
---
Variables:
- Name: addsconfig.ntpserver
Expression: |
($Parameter['addsconfig.ntpserver'] -split ',' | ForEach-Object {'{0},0x1' -f $_}) -join ' '